ALDRICH CHEMICAL CO -- BORON TRIFLUORIDE, 99.5+%, 29502-7 -- 6810-00N037930
=====================  Product Identification  =====================

Product ID:BORON TRIFLUORIDE, 99.5+%, 29502-7
MSDS Date:06/17/1992
FSC:6810
NIIN:00N037930
=== Responsible Party ===
Company Name:ALDRICH CHEMICAL CO
Box:355
City:MILWAUKEE
State:WI
ZIP:53201
Country:US
Info Phone Num:414-273-3850
Emergency Phone Num:414-273-3850
CAGE:60928
=== Contractor Identification ===
Company Name:ALDRICH CHEMICAL CO INC
Address:1001 WEST ST PAUL AVE
Box:355
City:MILWAUKEE
State:WI
ZIP:53233
Country:US
Phone:414-273-3850
CAGE:60928

=============  Composition/Information on Ingredients  =============

Ingred Name:BORON TRIFLUORIDE  (SARA III)
CAS:7637-07-2
RTECS #:ED2275000
Fraction by Wt: 99.5%+
OSHA PEL:1 PPM, C
ACGIH TLV:1 PPM, C

Ingred Name:SUPP DATA:BRTH VAPS. DO NOT GET IN EYES,ON SKIN, ON CLTHG.
    AVOID PRLNGD/RPTD EXPOS.DO NOT USE MERCURY MANOMETERS (ING 3)
RTECS #:9999999ZZ

Ingred Name:ING 2: AS BORON TRIFLUORIDE IS SOLUBLE IN MERCURY.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:MAY BE FATAL IF INHALED.
    MATERIAL IS EXTREMELY DESTUCTIVE TO TISSUE OF MUCOUS MEMBRANES &
    UPPER RESPITATORY TRACT, EYES AND SKIN. INHALATION MAY BE FATAL AS
    A RESULT OF SPASM, INFLAMMATION AND E DEMA OF LARYNX AND BRONCHI,
    CHEMICAL PNEUMONITIS AND PULMONARY EDEMA. SYMPTOMS OF EXPOSURE MAY
    (EFTS OF OVEREXPOS)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:INCLUDE BURNING SENSATION, COUGHING,
    WHEEZING, LARYNGITIS, SHORTNESS OF BREATH, HEADACHE, NAUSEA AND
    VOMITING. CHRONIC:DAMAGE TO KIDNEYS AND LUNGS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYES:IMMED FLUSH W/COPIOUS AMTS OF WATER FOR AT LEAST 15 MIN.
    ASSURE ADEQ FLUSHING BY SEPARATING LIDS W/FINGERS. SKIN:IMMED FLUSH
    WITH COPIOUS AMTS OF WATER FOR AT LEAST 15 MIN WHILE REMOVING
    CONTAM C LTHG & SHOES. INHAL:REMOVE TO FRESH AIR. IF NOT BRTHG GIVE
    ARTIF RESP. IF BRTHG IS DFCLT, GIVE OXYGEN. INGEST:WASH OUT MOUTH
    W/WATER PROVIDED PERSON IS CONSCIOUS. CALL MD. SYMPT MAY BE
    DELAYED.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:USE WATER SPRAY OR FOG NOZZLE TO KEEP CYLINDER
    COOL. MOVE CYLINDER AWAY FROM FIRE IF THERE IS NO RISK.
Fire Fighting Procedures:DANGER! USE NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT . POISONOUS AND COROSIVE NONFLAMMABLE LIQUID
    AND GAS UNDER PRESSURE.
Unusual Fire/Explosion Hazard:WATER HYDROLYZES MATL LIBERATING ACIDIC
    GAS WHICH IN CONT W/METAL SURF CAN GENERATE FLAMM AND/OR EXPLOS
    HYDROGEN GAS. EMITS TOX FUMES UNDER FIRE CONDITIONS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE AREA AND KEEP PERSONNEL UPWIND. WEAR
    FULL PROT EQUIP SUCH AS, A BUTYL RUBBER CHEM-PROOF AIR SUIT,
    W/BRTHG AIR SUPPLIED. SHUT OFF LEAK IF THERE IS NO RISK. VENT AREA
    & WASH SPILL SITE AFTER MA TL PICKUP IS COMPLETE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT BREATHE GAS. POISON. CORROSIVE.
    CYLINDER TEMPS SHOULD NOT EXCEED 125F (52C). STORE & USE W/ADEQ
    VENT. CONTENTS UNDER PRESS.
Other Precautions:WARNING:SUCK-BACK INTO CYLINDER MAY CAUSE RUPTURE.
    USE BACK-FLOW PREV DEVICE IN PIPING. USE W/EQUIP RATED FOR CYLINDER
    PRESS, & OF COMPATIBLE MATLS OF CONSTRUCTION. CLOSE VALVE WHEN NOT
    IN USE & WHEN  EMPTY. MAKE SURE CYLINDER IS (SUPDAT)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR IN NONVENTILLATED
    AREAS AND/OR FOR EXPOSURE ABOVE ACGIH TLV.
Ventilation:USE ONLY IN A CHEMICAL FUME HOOD.
Protective Gloves:COMPATIBLE CHEMICAL-RESISTANT GLOVES.
Eye Protection:CHEMICAL SAFETY GOGGLES.
Other Protective Equipment:SAFETY SHOWER AND EYE BATH.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
MATLS TO AVOID: INDUCTION PERIOD UP TO SEVERAL HRS.REACTS
    W/ALKALI/ALKALINE EARTH METALS. OTHER PREC:SECURED WHEN IN
    USE/STORED. HIGHLY TOX.VERY TOX BY INHAL, IN CONT W/SKIN & IF
    INGEST. CAUSES BURNS.  RISK OF EXPLOS IF HEATED UNDER CONFINEMENT.
    MOISTURE SENSIT. KEEP TIGHTLY CLSD. STORE AWAY FROM HEAT. DO NOT
    (ING 2)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:-148F,-100C
Melt/Freeze Pt:M.P/F.P Text:-197F,-127C
Vapor Density:2.38 @ 21C
Appearance and Odor:FUMING COLORLESS GAS.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
DO NOT ALLOW CONT W/WATER. FUMES STRONGLY IN MOIST AIR. AMINES. REACTS
    VIGOROUSLY W/ALKYL NITRATES AFTER AN (SUPP DATA)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:HYDROGEN FLUORIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH LOCAL, STATE
    AND FEDERAL REGULATIONS . CAUTION:NO-RETURN CYLINDER. DO NOT REUSE.
    EMPTY CYLINDER WILL CONTAIN HAZARDOUS RESIDUE. FOLLOW PROPER
    DISPOSAL TECHNIQ UES.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.