J.T.BAKER CHEMICAL CO -- FORMALDEHYDE, 37% SOLUTION -- 6810-00-242-3643
===================== Product Identification ===================== Product ID:FORMALDEHYDE, 37% SOLUTION MSDS Date:05/22/1990 FSC:6810 NIIN:00-242-3643 === Responsible Party === Company Name:J.T.BAKER CHEMICAL CO Address:222 RED SCHOOL LANE City:PHILLIPSBURG State:NJ ZIP:08865 Country:US Info Phone Num:800-JTBAKER Emergency Phone Num:201-859-2151/800-424-9300(CHEMTR) CAGE:DO870 === Contractor Identification === Company Name:J.T.BAKER CHEMICAL CO. Address:222 RED SCHOOL LANE City:PHILLIPSBURG State:NJ ZIP:08865-2219 Country:US Phone:201-859-2151 CAGE:DO870 Company Name:MALLINCKRODT BAKER, INC. Address:222 RED SCHOOL LANE Box:City:PHILLIPSBURG State:NJ ZIP:08865 Country:US Phone:800-582-2537 CAGE:70829 ============= Composition/Information on Ingredients ============= Ingred Name:FORMALDEHYDE (SARA III) CAS:50-00-0 RTECS #:LP8925000 Fraction by Wt: 37% Other REC Limits:NONE SPECIFIED OSHA PEL:SEE 1910.1048 ACGIH TLV:C 0.3 PPM; A2; 9293 EPA Rpt Qty:100 LBS DOT Rpt Qty:100 LBS Ingred Name:METHYL ALCOHOL (METHANOL) (SARA III) CAS:67-56-1 RTECS #:PC1400000 Fraction by Wt: 10-15% Other REC Limits:NONE SPECIFIED OSHA PEL:S,200PPM/250STEL ACGIH TLV:S,200PPM/250STEL; 93 EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS Ingred Name:WATER. CAS:7732-18-5 RTECS #:ZC0110000 Fraction by Wt: 47-53% ===================== Hazards Identification ===================== LD50 LC50 Mixture:LD50(ORAL RAT) IS 800 MG/KG-FORMALDEHYDE Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES Health Hazards Acute and Chronic:ACUTE-EYE:VAPORS CAUSE IRRITATION. SPLASHES MAY CAUSE IRREVERSIBLE DAMAGE. SKIN:MAY CAUSE BURNS, SEVERE IRRITATION. INHALATION:IRRITATION OF RESPIRATORY TRACT. INGESTION:MAY BE FATAL. MAY CAUSE GI IRR ITATION, BURNS TO MOUTH AND THROAT. CHRONIC-KIDNEY AND LIVER DAMAGE, SKIN SENSITIZATION. Explanation of Carcinogenicity:CONTAINS F [50-00-0] WHICH IS LISTED BY NTP AND IARC AND REGULATED BY OSHA AS A CARCINOGEN. Effects of Overexposure:EYE:TEARING, SEVERE EYE IRRITATION & BURN. SKIN:DRYING, CRACKING OF SKIN. INHALATION:HEADACHE, NAUSEA, VOMITING, DIZZINESS, VOMITING, DROWSINESS. INGESTION:NAUDEA, VOMTING, SEVERE STOMACH PAIN, SEVERE IRRITATION AND INFLAMMATION OF MOUTH, THROAT AND STOMACH. BLINDNESS OR DEATH MAY OCCUR. Medical Cond Aggravated by Exposure:EYE, SKIN, LIVER, KIDNEY AND RESPIRATORY DISORDERS MAY BE MORE SUSCEPTIBLE TO THE EFFECTS OF THE SUBSTANCE. ======================= First Aid Measures ======================= First Aid:INHALATION:REMOVE TO FRESH AIR, PROVIDE CPR/OXYGEN IF NEEDED. EYE CONTACT:FLUSH WITH WATER FOR 15 MINUTES. GET MEDICAL HELP. SKIN CONTACT:WASH WITH SOAP AND WATER. GET MED ATTENTION IF SYMPTOMS PERSIS T. INGESTION:INDUCE VOMITING, DRINK 1-2GLASSES OF WATER. GET MEDICAL HELP IMMEDIATELY. ===================== Fire Fighting Measures ===================== Flash Point:140F,60C Autoignition Temp:Autoignition Temp Text:858F Lower Limits:7.0% Upper Limits:73.0% Extinguishing Media:ALCOHOL FOAM, DRY CHEMICALS, CARBON DIOXIDE, WATER SPRAY. Fire Fighting Procedures:FIRE FIGHTERS SHOULD WEAR PROTECTIVE CLOTHING AND SELF-CONTAINED BREATHING APPARATUS. Unusual Fire/Explosion Hazard:VAPORS ARE HEAVIER THAN AIR, MAY SETTLE AT LOW AREAS OR TRAVEL SOME DISTANCE ALONG THE GROUND TO IGNITION SOURCES WHERE THEY MAY IGNITE & FLASH BACK. ================== Accidental Release Measures ================== Spill Release Procedures:VENTILATE AREA.REMOVE ALL SOURCES OF IGNITION.WEAR PROTECTIVE CLOTHING & RESPIRATOR.DO NOT FLUSH TO SEWER OR SURFACE WATERS. ABSORB WITH INERT MATERIAL AND PLACE INTO CONTAINERS FOR LATER DISPOSAL. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:STORAGE-STORE IN A DRY, WELL VENTILATED AREA ABOVE 15C. STORE WITH FLAMMABLE LIQUIDS. Other Precautions:PROTECT CONTAINER FROM FREEZING AND PHYSICAL DAMAGE. STORAGE AND USE AREAS SHOULD BE NO SMOKING AREAS.WEAR SPECIAL PROTECTIVE EQUIPMENT FOR MAINTENANCE BREAK-IN. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:USE NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS IF TLV IS EXCEEDED OR WHEN USING IN CONFINED SPACES. Ventilation:LOCAL OR GENERAL EXHAUST IS RECOMMENDED TO KEEP EMPLOYEE EXPOSURES BELOW THE AIRBORNE EXPOSURE LIMITS. Protective Gloves:CHEMICAL RESISTANT GLOVES Eye Protection:CHEMICAL SAFETY GOGGLES/FULL FACE SHIELD Other Protective Equipment:EYEWASH STATION AND SAFETY SHOWER.WEAR IMPERVIOUS CLOTHING,INCLUDING BOOTS,GLOVES,LAB COAT,APRON OR COVERALLS. Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND RECOMMENDED PROCEDURES. DO NOT WEAR CONTAMINATED CLOTHING OR FOOTWEAR. Supplemental Safety and Health THE PERCEPTION OF FORMALDEHYDE BY ODOR AND EYE IRRITATION BECOMES LESS SENSITIVE WITH TIME AS ONE ADAPTS TO FORMALDEHYDE. THIS CAN LEAD TO OVEREXPOSURE. HCC WAS DETERMINED BASED ON HIERCHY TABLE B-3 IN DLAM 4145.11/TM 38-410/NAVSUP PUB 573/AFJMAN 23-209/MCO 4450.12A. ================== Physical/Chemical Properties ================== HCC:F4 Boiling Pt:B.P. Text:204F,96C Vapor Pres:1.3 Vapor Density:1.0 Spec Gravity:1.08 pH:2.8 Solubility in Water:COMPLETE Appearance and Odor:CLEAR COLORLESS LIQUID,PUNGENT ODOR Percent Volatiles by Volume:100 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES STRONG OXIDIZERS, STRONG ALKALIES AND ACIDS, ALKALI METALS, AMINES AND AMMONIA, PHENOL AND REDUCING AGENTS. Stability Condition to Avoid:HIGH TEMPERATURES, SPARKS, AND OPEN FLAMES Hazardous Decomposition Products:FORMALDEHYDE AND CARBON MONOXIDE AND CARBON DIOXIDE. Conditions to Avoid Polymerization:TRIOXYMETHYLENE PRECIPITATE CAN BE FORMED ON LONG STANDING AT VERY LOW TEMP. NONHAZARDOUS PARAFORMALDEHYDE AT LOW TEMP. ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE OF IN AN APPROPRIATE DISPOSAL FACILITY IN COMPLIANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS. EPA HAZ WASTE # U122(TOXIC WASTE). IF SPILL IS IN EXCESS OF EPA REPORTABLE QUANTITY, NOTIFY THE NATIONAL RESPONSE CENTER (800-424-8802). Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.