FISHER SCIENTIFIC -- 1.10 PHENANTHROLINE MONOHYDRATE, P-70 -- 6810-00N041577
=====================  Product Identification  =====================

Product ID:1.10 PHENANTHROLINE MONOHYDRATE, P-70
MSDS Date:10/12/1992
FSC:6810
NIIN:00N041577
=== Responsible Party ===
Company Name:FISHER SCIENTIFIC
Address:1 REAGENT LANE
City:FAIR LAWN
State:NJ
ZIP:07410
Country:US
Info Phone Num:201-796-7100
Emergency Phone Num:201-796-7100;800-424-9300(CHEMTREC)
CAGE:1B464
=== Contractor Identification ===
Company Name:FISHER SCIENTIFIC CO.  CHEMICAL MFG DIV
Address:1 REAGENT LANE
Box:City:FAIRLAWN
State:NJ
ZIP:07410-2802
Country:US
Phone:201-796-7100
CAGE:1B464

=============  Composition/Information on Ingredients  =============

Ingred Name:ING 4:W/DUST & MIST FILTER. ANY NIOSH/MSHA APPRVD POWERED
    AIR-PURIFYING RESP W/HEPA FILTER. ANY NIOSH/MSHA APPRVD(ING 6)
RTECS #:9999999ZZ

Ingred Name:ING 5: TYPE 'C' SUPP-AIR RESP OPER IN PRESS-DEMAND/OTHER
    POS PRESS OR CONTINUOUS-FLOW MODE. ANY NIOSH/MSHA APPRVD(ING 7)
RTECS #:9999999ZZ

Ingred Name:ING 6: SCBA. FOR FIREFIGHTING & OTHER IDLH CNDTNS: ANY
    NIOSH/MSHA APPRVD SCBA THAT HAS FULL FACEPIECE & IS OPER (ING 8)
RTECS #:9999999ZZ

Ingred Name:ING 7: IN PRESS-DEMAND OR OTHER POS-PRESS MODE. ANY
    NIOSH/MSHA APPRVD SUPP-AIR RESP THAT HAS FULL FACEPIECE & IS (ING
    9)
RTECS #:9999999ZZ

Ingred Name:ING 8: OPER IN PRESS-DEMAND OR OTHER POS-PRESS MODE IN
    COMBINATION W/AN AUXILIARY SCBA OPER IN PRESS-DEMAND OR (ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 9: OTHER POSITIVE-PRESSURE MODE.
RTECS #:9999999ZZ

Ingred Name:1,10-PHENANTHROLINE, MONOHYDRATE; (PHENANTHROLINE,
    MONOHYDRATE)
CAS:5144-89-8
RTECS #:SF8437000
Fraction by Wt: 100%

Ingred Name:SUPP DATA:MED ATTN IMMED.IF VOMIT OCCURS, KEEP HEAD LOWER
    THAN HIPS TO PVNT ASPIR. ANTIDOTE:NO SPECIFIC ANTIDOTE.(ING 3)
RTECS #:9999999ZZ

Ingred Name:ING 2: TREAT SYMPTOMATICALLY AND SUPPORTIVELY.
RTECS #:9999999ZZ

Ingred Name:RESP PROT: NIOSH/MSHA APPRVD AIR-PURIFYING RESP W/HEPA
    FILTER. ANY NIOSH/MSHA APPRVD POWERED AIR-PURIFYING RESP (ING 5)
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION: MAY BE IRRITATING
    TO RESPIRATORY TRACT. SKIN: MAY BE IRRITATING. EYE: MAY BE
    IRRITATING. INGESTION: NO DATA AVAILABLE. CHRONIC: NO DATA
    AVAILABLE.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHAL:REMOVE FROM EXPOS AREA TO FRESH AIR IMMED. IF BRTHG HAS
    STOPPED, PERFORM ARTF RESP. KEEP PERSON WARM & AT REST. TREAT SYMP
    & SUPPORTIVELY. GET MED ATTN IMMED. SKIN: REMOVE CONTAMD CLTHG &
    SHOES  IMMED. WASH AFFECTED AREA W/SOAP/MILD DETERGENT & LRG AMTS
    OF WATER UNTIL NO EVIDENCE OF CHEM REMAINS (APPROX 15-20 MINS). GET
    MED ATTN IMMED. EYE: WASH IMMED W/LRG AMTS OF WATER/NORM SALINE,
    (SUPDAT)

=====================  Fire Fighting Measures  =====================

Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, WATER SPRAY OR
    REGULAR FOAM. FOR LARGER FIRES, USE WATER SPRAY, FOG OR REGULAR
    FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
    .MOVE CNTNR FROM FIRE AREA IF YOU CAN DO IT W/OUT RISK. DO NOT
    SCATTER SPILLED MATL WITH HIGH-PRESS (SUPDAT)
Unusual Fire/Explosion Hazard:SLIGHT FIRE HAZARD WHEN EXPOSED TO HEAT
    OR FLAME.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SWEEP UP AND PLACE IN SUITABLE CLEAN, DRY
    CONTAINERS FOR RECLAMATION OR LATER DISPOSAL. DO NOT FLUSH MATERIAL
    INTO SEWER. KEEP UNNECESSARY PEOPLE AWAY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:OBSERVE ALL FED,ST & LOC REGS WHEN
    STORING OF SUBSTANCE. FOR ASSIST CONT DISTRICT DIRECTOR OF ENVIRON
    PROT AGENCY.STORE AWAY FROM INCOMPAT SUBSTANCES.
Other Precautions:MAY BURN BUT DOES NOT IGNITE READILY. AVOID CONTACT
    WITH STRONG OXIDIZERS, EXCESSIVE HEAT, SPARKS, OR OPEN FLAME.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:SPECIFIC RESP SELECTED MUST BE BASED ON CONTAM
    LEVS FOUND IN WORK PLACE, MUST BE BASED ON SPECIFIC OPER, MUST NOT
    EXCEED WORKING LIMITS OF RESP & MUST BE JOINTLY APPRVD BY
    NIOSH/MSHA. ANY NIOSH/MSHA A PPRVD DUST & MIST RESP. ANY (ING 4)
Ventilation:PROVIDE LOCAL EXHAUST VENTILATION. VENTILATION EQUIPMEMT
    MUST BE EXPLOSION PROOF.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:SPLSH-PRF OR DUST RESIST (OTR PROT EQPT)
Other Protective Equipment:IMPERVIOUS CLOTHING AND EQUIPMENT, EMERGENCY
    EYEWASH. EYE PROT: SAFETY GOGGLES.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC: WATER STREAMS. DIKE FIRE-CNTRL WATER FOR LATER DISP.
    USE AGENTS SUITABLE FOR SURROUNDING FIRE. AVOID BRTHG HAZ VAPS,
    KEEP UPWIND. FIRST AID PROC: FOR AT LST 15 MINS, OCCAS LIFTING UPP
    ER & LOWER LIDS, UNTIL NO EVIDENCE OF CHEM REMAINS. GET MED ATTN
    IMMED. INGEST: TREAT SYMP & SUPPORTIVELY. GET (ING 2)

==================  Physical/Chemical Properties  ==================

Melt/Freeze Pt:M.P/F.P Text:>199F,>93C
Solubility in Water:0.33%
Appearance and Odor:WHITE CRYSTALLINE POWDER WITH SLIGHT ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
OXIDIZERS (STRONG): FIRE AND EXPLOSION HAZARD.
Stability Condition to Avoid:EXCESSIVE HEAT, SPARKS, OR OPEN FLAME.
Hazardous Decomposition Products:THERMAL DECOMPOSITION PRODUCTS MAY
    INCLUDE TOXIC OXIDES OF CARBON AND NITROGEN.

====================  Disposal Considerations  ====================

Waste Disposal Methods:OBSERVE ALL FEDERAL, STATE AND LOCAL REGULATIONS
    WHEN DISPOSING OF SUBSTANCE. FOR ASSISTANCE CONTACT DISTRICT
    DIRECTOR OF EPA. DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE, AND
    LOCAL REGULATIONS (FP N ).

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.