SIGMA CHEMICAL COMPANY -- H1009;HYDROGEN PEROXIDE 30%(W/W) SOLUTION -- 6810-00-299-8506
=====================  Product Identification  =====================

Product ID:H1009;HYDROGEN PEROXIDE 30%(W/W) SOLUTION
MSDS Date:02/27/1996
FSC:6810
NIIN:00-299-8506
=== Responsible Party ===
Company Name:SIGMA CHEMICAL COMPANY
Box:14508
City:ST. LOUIS
State:MO
ZIP:63178
Country:US
Info Phone Num:314-771-5765
Emergency Phone Num:314-771-5765
CAGE:21076
=== Contractor Identification ===
Company Name:SIGMA CHEMICAL COMPANY
Address:3050 SPRUCE ST
Box:14508
City:ST LOUIS
State:MO
ZIP:63178
Country:US
Phone:314-771-5765
CAGE:21076

=============  Composition/Information on Ingredients  =============

Ingred Name:HYDROGEN PEROXIDE (SARA III)
CAS:7722-84-1
RTECS #:MX0900000
Fraction by Wt: 30%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1 PPM
ACGIH TLV:1 PPM; 9394

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL LD50 (RAT) IS 1518MG/KG
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:YES	 OSHA:NO
Health Hazards Acute and Chronic:CORROSIVE--EYES:MAY CAUSE
    IRRITATION.SKIN: MAY CAUSE IRRITATION.MAY BE DERMALLY ABSORBED IN
    HARMFUL AMOUNTS.INGEST:MAY CAUSE GI TRACT IRRITATION.INHAL:MAY BE
    FATAL AS A RESULT OF SPASM,INFLAMMATION AN D EDEMA OF THE LARNYX
    AND BRONCHII,CHEMICAL PNEUMONITIS AND PULMONARY EDEMA.
Explanation of Carcinogenicity:MUTAGENIC EFFECTS HAVE BEEN SHOWN IN
    LABORATORY EXPERIMENTS.
Effects of Overexposure:INHAL:BURNING
    SENSATION,COUGHING,WHEEZING,LARYNGITIS,SHORTNESS OF
    BREATH,HEADACHE,NAUSEA,VOMITING.
Medical Cond Aggravated by Exposure:PREGNANT WOMEN MAY BE AT INCREASED
    RISK FROM EXPOSURE.

=======================  First Aid Measures  =======================

First Aid:SKIN:REMOVE CONTAMINATED CLOTHING;WASH WITH SOAP AND
    WATER.EYES:FLUSH WITH WATER FOR 15 MINUTES.INHAL:REMOVE TO FRESH
    AIR.GIVE OXYGEN OR ARTIFICIAL RESPIRATION IF NEEDED.INGEST:DO NOT
    INDUCE VOMITING. GET PROMPT QUALIFIED MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Extinguishing Media:USE WATER SPRAY.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
    FULL FACED SELF CONTAINED BREATHING APPARATUS. COOL FIRE EXPOSED
    CONTAINERS WITH WATER FOG.
Unusual Fire/Explosion Hazard:**OXIDIZER** CONTACT WITH OXIDIZABLE
    MATERIALS MAY CAUSE VIOLENT REACTION;FIRE MAY OCCUR WHEN HYDROGEN
    PEROXIDE DRIES ON COMBUSTIBLE MATERIALS(HMIS-LEVIEN).

==================  Accidental Release Measures  ==================

Spill Release Procedures:VENTILATE AREA;DILUTE WITH LARGE AMOUNTS OF
    WATER UNTIL THE HYDROGEN PEROXIDE HAS DECOMPOSED;HOLD MATERIAL IN A
    POND OR DIKE.SOAK UP WITH A NON-COMBUSTIBLE ABSORBANT;PLACE IN
    SUITABLE VENTED CONTAINER S,HELD IN WELL-VENTILATED AREA;DISPOSE OF
    PROPERLY
Neutralizing Agent:USE WATER TO DILUTE AND DECOMPOSE HYDROGEN PEROXIDE.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL, DRY, WELL VENTILATED
    AREA. KEEP CONTAINERS TIGHTLY CLOSED WHEN NOT IN USE. PROTECT
    CONTAINERS FROM HEAT,LIGHT,OXIDIZERS,REDUCERS.
Other Precautions:DO NOT TAKE INTERNALLY. DO NOT BREATHE MIST. AVOID
    CONTACT WITH EYES. WASH THOROUGHLY AFTER HANDLING.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:WHERE ENVIRONMENTAL CONTROLS ARE LACKING OR IN
    ENCLOSED SPACES USE EITHER A SELF-CONTAINED BREATHING APPARATUS OR
    A NOISH/ MSHA APPROVED RESPIRATOR FOR ACID GAS,DEPENDING ON THE
    AIRBORN CONCENTRATION.
Ventilation:LOCAL VENTILATION AT THE WORKSITE;MECHANICAL(GENERAL)
    VENTILATION TO MAINTAIN TLV/PEL.
Protective Gloves:ACID RESISTANT
Eye Protection:CHEMICAL SPLASH GOGGLES
Other Protective Equipment:PROTECTIVE CLOTHING,AS NEEDED.PROVIDE A
    LOCAL EYE WASH STATION AND SAFETY SHOWER.
Work Hygienic Practices:WASH HANDS.SEPERATE WORK CLOTHES FROM STREET
    CLOTHES.LAUNDER WORK CLOTHES BEFORE REUSE.KEEP FOOD OUT OF THE WORK
    AREA.
Supplemental Safety and Health
MFR MSDS AUGMENTED WITH CCINFO-MSDS(HMIS-
    LEVIEN).INCOMPATABILITY:BRASS,COPPER,COPPER ALLOYS,GALVANIZED
    IRON,ZINC,NICKEL,LEAD,RUST,FINELY POWDERED METALS,IRON AND IRON
    SALTS,CHROMIUM,SILVER,PALLADIUM. FORMS EXPLOSIVE MIXTURES WITH
    KETONES,ETHERS,CARBOXYLIC
    ACIDS,ANHYDRIDES,ALCOHOLS,HYDRAZINE,ANALINE,SODIUM FLUORIDE.

==================  Physical/Chemical Properties  ==================

HCC:D3
Vapor Pres:23.3@86F
Vapor Density:1
Spec Gravity:1.11
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID;CLEAR;ACRID ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS,ORGANIC MATERIALS(ESP.TEXTILES AND
    PAPER),REDUCING AGENTS,REACTIVE METALS.SEE SUPPLIMENTAL DATA.
Stability Condition to Avoid:LIGHT SENSITIVE.HIGH HEAT CAUSES
    DECOMPOSITION AND PRESSURE BUILD-UP(HMIS-LEVIEN).
Hazardous Decomposition Products:OXYGEN,WATER(WITH HEAT AND
    PRESSURE;VENT CONTAINERS).

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL,STATE AND
    LOCAL REGULATIONS.CAUTIOUSLY ACIDIFY 3% SOLUTION TO PH2 WITH
    H2SO4.GRADUALLY ADD 50% EXCESS OF SODIUM BISULFAITE(AQ) WITH
    STIRRING AT ROOM TEMPERATURE.R ISE IN TEMPERATURE INDICATES
    REACTION TAKING PLACE

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.