AIRCO, DIVISION OF THE BOC GROUP, INC. -- ACETYLENE -- 6830-00-270-8216
=====================  Product Identification  =====================

Product ID:ACETYLENE
MSDS Date:05/09/1989
FSC:6830
NIIN:00-270-8216
=== Responsible Party ===
Company Name:AIRCO, DIVISION OF THE BOC GROUP, INC.
Address:575 MOUNTAIN AVENUE
City:MURRAY HILL
State:NJ
ZIP:07974-2006
Country:US
Info Phone Num:201-464-8100
Emergency Phone Num:800-424-9300(CHEMTREC)
CAGE:IO644
=== Contractor Identification ===
Company Name:AIRCO INC, AIRCO INDUSTRIAL GASES DIV.
Address:575 MOUNTAIN AVE
Box:City:MURRAY HILL
State:NJ
ZIP:07974-2006
Country:US
Phone:800-424-9300(CHEMTREC)
CAGE:00741
Company Name:AIRCO, DIVISION OF THE BOC GROUP, INC.
Address:575 MOUNTAIN AVENUE
City:MURRAY HILL
State:NJ
ZIP:07974
Country:US
Phone:201-464-8100
CAGE:IO644

=============  Composition/Information on Ingredients  =============

Ingred Name:ACETYLENE (SIMPLE ASPHYXIANT)
CAS:74-86-2
RTECS #:AO9600000
Fraction by Wt: 100.000%
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:SKIN: IRRITATION, DERMATITIS. INHAL:
    CNS TOXIN (HEADACHE, NAUSEA, DIZZY, VOMIT, FATIGUE). INTOXICATED,
    HYPERCAPNIA, DELETERIOUS EFFECTS, ASPHYZIANT, DIZZY, DEEPER
    BREATHING, NAUSEA UNCONSCIOUSNESS.

=======================  First Aid Measures  =======================

First Aid:INHAL: PROMPT MEDICAL ATTENTION MANDATORY IN CASES OF
    OVEREXPOSURE. ASSIST VICTIMS TO FRESH AIR. QUICK REMOVAL TO FRESH
    AIR IS MOST IMPORTANT. ARTIFICIAL RESUSCITATION OR OXYGEN IF
    NEEDED.  KEEP WARM	& QUIET. SKIN: WASH WITH SOAP & WATER. IN ALL
    CASES, GET MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point:GAS
Autoignition Temp:Autoignition Temp Text:565F
Lower Limits:2.2%
Upper Limits:80-85 *
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL. * PURE ACETYLENE CAN
    IGNITE BY DECOMP >15 PSI,UEL 100% IF IGNIT INTENSE.
Fire Fighting Procedures:STOP FLOW OF GAS SUPPLY. ALLOW FUEL TO CONSUME
    ITSELF. USE WATER SPRAY TO COOL ADJACENT AREAS. KEEP PERSONNEL
    AWAY, HEATED/BURNING CYLINDERS CAN RUPTURE.
Unusual Fire/Explosion Hazard:SPONTANEOUSLY COMBUSTIBLE IN AIR AT
    PRESSR >15PSI.REQ VERY LOW IGNIT(FIRES EXTINGUISHED W/O STOP FLOW
    OF GAS CAN REIGNITE).LEAKING AIR WONT READILY DISSIPATE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:USE PROTECTIVE EQUIPMENT. IF LEAK IN USERS
    EQUIPMENT, BE CERTAIN TO PURGE PIPING W/INERT GAS PRIOR TO
    ATTEMPTING REPAIRS. IF LEAK IN CONTAINER/CONTAINER VALVE, CONTACT
    CHEMTREC FOR EMERGENCY ASSISTANC E OR CALL CLOSEST AIRCO LOCATION.

======================	Handling and Storage  ======================

Handling and Storage Precautions:SECURE VALVE PROTECTION CAPS IN PLACE
    UNLESS CONTAINER SECURED W/VALVE PROTECTN OUTLET PIPED TO USE
    POINT. DONT DRAG/SLIDE/ROLL CYLINDERS.**
Other Precautions:**USE HAND TRUCK TO MOVE.USE PRESSURE REDUCING
    REGULATOR WHEN REMOVING GAS FROM CYLINDER.DONT ALLOW FREE GAS TO
    >15 PSI @ 70F.DONT HEAT CYLINDER TO INCREASE FLOW.USE CHECK VALVE
    OR TRAP IN DISCHARGE L INE TO PREVENT HAZARDOUS BACK FLOW.***

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:POSITIVE PRESSURE AIR LINE WITH MASK OR SCBA
    SHOULD BE AVAILABLE FOR EMERGENCY USE.
Ventilation:HOOD W/FORCED VENTILATION. LOCAL EXHAUST TO PREVENT
    ACCUMULATION ABOVE EXPOSURE LIMIT. MECHANICAL W/ELECTRICAL CODES.
Protective Gloves:PVC, RUBBER OR AS REQUIRED.
Eye Protection:SAFETY GOGGLES OR GLASSES.
Other Protective Equipment:SAFETY SHOES, SAFETY SHOWERS.
Supplemental Safety and Health
***STORE IN COOL, DRY, VENTILATED AREA OF NON-COMBUSTIBLE
    CONTSTRUCTION. DONT ALLOW TEMPS >130F. STORE CYLINDERS UPRIGHT AND
    FIRMLY SECURED.USE "FIRST IN-FIRST OUT" INVENTORY. POST "NO SMOKING
    OR OPEN  FLAME" SIGNS IN STORAGE OR USE AREA. NO INGIT SOURCES IN
    STORAGE OR USE AREA.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:-182F,-119C
Melt/Freeze Pt:M.P/F.P Text:-113F,-81C
Vapor Pres:645 PSIA
Spec Gravity:0.906
Solubility in Water:SOLUBLE
Appearance and Odor:COLORLESS GAS.PURE ACETYLENE-ETHERAL ODOR;
    COMMRCL(CARBIDE)ACETYLENE-GARLIC LIK

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:NO
OXYGEN & OTHER OXIDIZER, HALOGENS & HALOGEN COMPOUNDS. FORM EXPLOSIVE
    COMPOUNDS W/COPPER, MERCURY, SILVER, ETC.
Stability Condition to Avoid:DONT ALLOW FREE GAS (OUTSIDE OF CYLINDER)
    TO EXCEED 15 PSI. DONT EXPOSE CYLINDERS TO SUDDEN SHOCK OR HEAT.
Hazardous Decomposition Products:CARBON MONOXIDE AND HYDROGEN.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DONT ATTEMPT TO DISPOSE OF WASTE OR UNUSED
    QUANTITIES. RETURN IN THE SHIPPING CONTAINER PROPERLY LABELED,
    W/ANY VALVE OUTLET PLUGS OR CAPS SECURED & VALVE PROTECTION CAP IN
    PLACE TO AIRCO LOCATION FOR  PROPER DISPOSAL.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.