CHIRON DIAGNOSTICS -- 4 MOLAR POTASSIUM CHLORIDE SOLUTION, 477428 -- 6505-01-041-9871
=====================  Product Identification  =====================

Product ID:4 MOLAR POTASSIUM CHLORIDE SOLUTION, 477428
MSDS Date:01/06/1997
FSC:6505
NIIN:01-041-9871
Status Code:A
=== Responsible Party ===
Company Name:CHIRON DIAGNOSTICS
Address:63 NORTH ST
City:MEDFIELD
State:MA
ZIP:02052
Country:US
Info Phone Num:800-255-2121
Emergency Phone Num:800-888-8372
CAGE:JO058
=== Contractor Identification ===
Company Name:CHIRON DIAGNOSTICS CORP
Address:63 NORTH ST
City:MEDFIELD
State:MA
ZIP:02052
Country:US
Phone:800-255-2121
CAGE:JO058

=============  Composition/Information on Ingredients  =============

Ingred Name:POTASSIUM CHLORIDE. LD50:(ORAL,RAT) 2600 MG/KG.
CAS:7447-40-7
RTECS #:TS8050000
Fraction by Wt: 25-30%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:WASTE DISP METH:PHENOLS, PESTICIDES/POLYCHLORINATED
    BIPHENYLS (THAT IS, NO CHEMS ON EPA TOX POLLUTANT LIST (ING 3)
RTECS #:9999999ZZ

Ingred Name:ING 2:(40 CFR 401.15). HOWEVER, IN ORDER TO DETERMINE
    PROPER DISPOSAL, CONSULT APPLICABLE LOCAL, STATE & FEDERAL REGS.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:SEE INGREDIENT 1.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYE:IRRITATION. SKIN
    CONTACT:IRRITATION. SKIN ABSORPTION:NOT ABSORBED THROUGH SKIN.
    INGESTION:MAY BE HARMFUL. INGESTION OF LARGE QUANTITIES MAY CAUSE
    WEAKNESS, GASTROINTESTINAL IRRITATION AND CI RCULATORY
    DISTURBANCES. INHALATION:MAY BE HARMFUL. TARGET ORGANS:EYES, SKIN.
    CHRONIC:NOT ESTABLISHED.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NOT ESTABLISHED.

=======================  First Aid Measures  =======================

First Aid:EYES:FLUSH W/WATER FOR A MINIMUM OF 15 MINUTES. SKIN:WASH
    W/SOAP & WATER FOR A FEW MINUTES THEN CONTINUE TO FLUSH W/WATER FOR
    A TOTAL OF 15 MINUTES. INHAL:REMOVE TO FRESH AIR. INGEST:CALL MD.
    NOTE:AFT ER FOLLOWING FIRST AID MEASURES, SEEK PROFESSIONAL MEDICAL
    ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point:NOT FLAMMABLE
Extinguishing Media:MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT . STANDARD FIRE-FIGHTING PRECAUTIONS SHOULD BE FOLLOWED
    WHEN TRYING TO EXTINGUISH ANY FIRE.
Unusual Fire/Explosion Hazard:NONE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VAPS OF SPILLED MATL:VAP DENSITY RELATIVE TO
    AIR - NON-FLAMM; DOES NOT GIVE OFF SIGNIFICANT AMTS OF VAP. IF MATL
    RELS/SPILLED:ABSORB SPILLED MATL. WASH AFFECTED SURFS W/SOAP &
    WATER. SPILLS MUST BE HN DLD BY TRAINED PERS. FOR APPROP PPE
    FOR(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORAGE TEMP(MIN/MAX):SEE PROD PACKAGE
    INSERT. AVOID BREATHING VAPORS/AEROSOLIZED MATL. AVOID CONTACT
    W/EYES. AVOID PRLNG/RPTD CONTACT W/SKIN.
Other Precautions:HARMFUL. IRRITANT. KEEP CONTAINERS CLOSED WHEN NOT IN
    USE. HARMFUL BY INHALATION, IN CONTACT W/SKIN & IF SWALLOWED.
    IRRITATING TO EYES, RESPIRATORY SYSTEM & SKIN. THIS PRODUCT SHOULD
    BE HANDLED I/A/W  GOOD LAB PRACTICES.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH APPROVED RESPIRATORY PROTECTION MAY BE
    REQUIRED IF EXPOSURE TO HAZARDOUS INGREDIENTS MAY EXCEED RECOGNIZED
    SAFE LIMITS.
Ventilation:HANDLE IN AN AREA W/GOOD GENERAL ROOM VENTILATION.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS &(SUPDAT)
Other Protective Equipment:ANSI APPRVD EYE WASH FOUNTAIN & DELUGE
    SHOWER . STD PPE FOR LAB WORK INCLS LAB COAT (CHEM RESIST APRON/
    (SUPDAT)
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
SPILL PROC:RESPONDING TO SPILL/RELS, SEE EXPOS CONTROLS/PERSONAL PROT
    SECTION. THIS MATL/ITS VAPS WHEN SPILLED IN QTYS ROUTINELY IN USE
    DOES NOT CAUSE SEV/IMMED HLTH EFTS/REQ IMMED RECOGNITION TO PVNT 
    SUBSEQUENT SERIOUS EFTS. EYE PROT:FULLLGTH FSHLD . OTHER PROT
    EQUIP:SUIT, IF LG VOL).

==================  Physical/Chemical Properties  ==================

Spec Gravity:1.02
Solubility in Water:SOLUBLE
Appearance and Odor:COLORLESS LIQUID; ODORLESS.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG ACIDS & WATER REACTIVE MATERIALS SUCH
    AS ELEMENTAL SODIUM & POTASSIUM.
Stability Condition to Avoid:FREEZING OR BOILING THE PRODUCT.
Hazardous Decomposition Products:FUMES OF POTASSIUM OXIDE & CHLORIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF I/A/W FED, STATE & LOCAL REGS. REFER
    TO INGS SECTION & STABILITY & REACTIVITY SECTION. PROD IS NOT
    CLASSIFIED AS HAZ WASTE ACCORDING TO EPA REGS(40 CFR 261). PROD
    DOES NOT CONTAIN HEAVY MET ALS, VOLATILE/SEMI-VOLATILE ORGANIC
    CMPDS, (ING 2)

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.