NATIONAL DIAGNOSTICS INC -- BASIC FUCHSIN, HS-518 -- 6810-00N067358
=====================  Product Identification  =====================

Product ID:BASIC FUCHSIN, HS-518
MSDS Date:10/06/1987
FSC:6810
NIIN:00N067358
=== Responsible Party ===
Company Name:NATIONAL DIAGNOSTICS INC
Address:1013-1017 KENNEDY BLVD
City:MANVILLE
State:NJ
ZIP:08835
Country:US
Info Phone Num:201-722-8600;800-526-3867
Emergency Phone Num:201-722-8600;800-526-3867
CAGE:58215
=== Contractor Identification ===
Company Name:NATIONAL DIAGNOSTICS INC
Address:1013-1017 KENNEDY BLVD
Box:City:MANVILLE
State:NJ
ZIP:08835
Country:US
CAGE:58215

=============  Composition/Information on Ingredients  =============

Ingred Name:BENZENAMINE, 4-((4-AMINOPHENYL)(4-IMINO-2,5-
    CYCLOHEXADIEN-1-YLIDENE)METHYL), MONOHYDROCHLORIDE; (PARAROSANILIN,
    (ING 2)
CAS:569-61-9
RTECS #:CX9850100
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:ING 1: BASIC RED 9, C.I. #42500)
RTECS #:9999999ZZ
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO	Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:DUST MAY IRRITATE SKIN OR EYES.
    CHRONIC:NONE LISTED BY MANUFACTURER.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:CALL A PHYSICIAN. INGEST:IF CONSCIOUS, IMMED INDUCE VOMIT.
    INHAL:REMOVE TO FRESH AIR. IF NOT BRTHG, GIVE ARTF RESP. IF BRTHG
    IS DFCLT, GIVE OXYG. EYES:IMMED FLUSH WITH PLENTY OF WATER FOR @
    LEAST 15 M INS. SKIN:FLUSH WITH WATER.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:USE EXTINGUISHING MEDIA APPROPRIATE FOR SURROUNDING
    FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVEVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

==================  Accidental Release Measures  ==================

Spill Release Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT CLTHG.
    WITH CLEAN SHOVEL, CAREFULLY PLACE MATL INTO CLEAN, DRY CONTAINER
    AND COVER; REMOVE FROM AREA. FLUSH SPILL AREA WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP CONTAINER TIGHTLY CLOSED.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
    EXPOSURE OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:WEAR IMPERVIOUS CLOTHING. ANSI APPRVD
    EMERGENCY EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

==================  Physical/Chemical Properties  ==================

Solubility in Water:0.1-1.0%
Appearance and Odor:GREEN CRYSTALLINE POWDER.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL APPLICABLE
    FEDERAL, STATE, AND LOCAL ENVIRONMENTAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.